High Voltage 18/30kv Copper Conductor XLPE Insulated Power Cable

Model NO.: 1X630sq. Mm
Certification: ISO, CCC
Model: Yjv,Yjy
Brand: Jytop
Trademark: JYTOP
Transport Package: Packed in Reels
Specification: any Third party Pre-shipment inspection
Origin: Zhengzhou, China
HS Code: 8544601200
Model NO.: 1X630sq. Mm
Certification: ISO, CCC
Model: Yjv,Yjy
Brand: Jytop
Trademark: JYTOP
Transport Package: Packed in Reels
Specification: any Third party Pre-shipment inspection
Origin: Zhengzhou, China
HS Code: 8544601200
High voltage 18/30KV Copper conductor XLPE INSULATED POWER CABLE
High Voltage 18/30kv Copper Conductor XLPE Insulated Power Cable

1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.

2. Operating Characteristics
Rated voltage U0/U(Um): 18/30(36)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For three core cable: Not less than 15 times of the diameter of cable

3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.

4. Manufacturing Standards
IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

KINDLY NOTE: If you want to know more details about this kind of products, please visit our website:www.jytopcable.com   for further information.  Thanks.
 
 
Size
(sq.mm)
Nominal thickness of XLPE insulation(mm) Approx. thickness of copper tape screen (mm) Nominal thickness of PVC or PE(mm) Approx. overall diameter of finished cable(mm) Max. conductor D.C resistance @ 20 0 C (Ω/km)
1x50 8.0 0.12 1.9 32.2 0.387
1x70 8.0 0.12 2.0 34.1 0.268
1x95 8.0 0.12 2.1 35.9 0.193
1x120 8.0 0.12 2.1 37.3 0.153
1x150 8.0 0.12 2.1 38.9 0.124
1x185 8.0 0.12 2.2 40.7 0.0991
1x240 8.0 0.12 2.3 43.3 0.0754
1x300 8.0 0.12 2.3 45.3 0.0601
1x400 8.0 0.12 2.5 48.9 0.0470
1x500 8.0 0.12 2.5 52.6 0.0366
1x630 8.0 0.12 2.7 56.6 0.0283
1x800 8.0 0.12 2.8 60.6 0.0221
High voltage 18/30KV Copper conductor XLPE INSULATED POWER CABLE
High Voltage 18/30kv Copper Conductor XLPE Insulated Power Cable

1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.

2. Operating Characteristics
Rated voltage U0/U(Um): 18/30(36)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For three core cable: Not less than 15 times of the diameter of cable

3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.

4. Manufacturing Standards
IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

KINDLY NOTE: If you want to know more details about this kind of products, please visit our website:www.jytopcable.com   for further information.  Thanks.
 
 
Size
(sq.mm)
Nominal thickness of XLPE insulation(mm) Approx. thickness of copper tape screen (mm) Nominal thickness of PVC or PE(mm) Approx. overall diameter of finished cable(mm) Max. conductor D.C resistance @ 20 0 C (Ω/km)
1x50 8.0 0.12 1.9 32.2 0.387
1x70 8.0 0.12 2.0 34.1 0.268
1x95 8.0 0.12 2.1 35.9 0.193
1x120 8.0 0.12 2.1 37.3 0.153
1x150 8.0 0.12 2.1 38.9 0.124
1x185 8.0 0.12 2.2 40.7 0.0991
1x240 8.0 0.12 2.3 43.3 0.0754
1x300 8.0 0.12 2.3 45.3 0.0601
1x400 8.0 0.12 2.5 48.9 0.0470
1x500 8.0 0.12 2.5 52.6 0.0366
1x630 8.0 0.12 2.7 56.6 0.0283
1x800 8.0 0.12 2.8 60.6 0.0221

Outdoor Front Service LED Display

Front Service Outdoor Fixed Install LED Display Screen


1. High refresh rate: With NOVA STAR control system, no scanning line when photographed
2. High gray level: 256 RGB each ,display 16.7M colors ,vivid and perfect video effect
3.High resolution: The most apparent features of the new generation of LED display
4.Good color uniformity
5. High Brightness: 6000-8000 cd/m2 ,brightness automatically adjusted
6. High Quality: CE, RoHs, FCC, UL, IP65, ISO9001 passed + 96 Hours serious testing time
7. Long life span: over100,000hours, warranty from 2 years.



* Nova MSD 300 sending card and Nova mrv328 receiving card

* Cabinet size:960x960mm

* Kinglight/Nationstar LED Lamp, Refresh rate:1920-3840hz

* Ultra-Light designing, less than 30kg/pcs

* High brightness up to 6500cd/sq.m, even in the sunlight conditions can see clear, but low power consumption to save the electric power cost.

* High debugging brightness and no damage to gray scale, achieving the debugging technology for nice image.

* Passed the TÜV,FCC,ROHS,CE cetification.

Outdoor Front Service LED Display,P3.91 Outdoor Led Screen,Led Stage Screen

Guangzhou Chengwen Photoelectric Technology co.,ltd , https://www.cwledpanel.com