Hisense Central Air Conditioner: Cool and comfortable family summer artifact

As central air-conditioning systems become increasingly common, Hisense’s central air-conditioning units are standing out with their impressive features. Known for their powerful airflow, these units offer comprehensive coverage without any blind spots, thanks to the innovative NANOETM technology. Hisense’s central air-conditioning units are celebrated for their thoughtful design elements, which enhance both comfort and health. They effectively regulate humidity levels and eliminate bacteria, fostering a healthier living environment. Recent reports indicate that Hisense Central Air Conditioning has maintained a remarkable compound annual growth rate exceeding 30% in China. Even in the home renovation retail sector, it has seen explosive growth rates surpassing 60%. This demonstrates a growing consumer awareness of the benefits of Hisense's central air-conditioning systems. One standout feature is the absence of any unconditioned zones. Unlike conventional wall-mounted or cabinet air conditioners, Hisense central air-conditioning systems utilize a centralized cooling source and multiple distribution systems. A single outdoor unit can power several indoor units, significantly increasing the area covered by cooling. Additionally, since the indoor units are installed within the ceiling spaces, they minimize direct exposure to cold air, ensuring a comfortable and evenly distributed airflow throughout your home. ![Image](http://i.bosscdn.com/blog/15/01/66/9152768.png) Another key advantage of Hisense central air-conditioning systems is their advanced fresh-air monitoring capabilities. These systems continuously assess indoor air quality, introducing fresh air from outside when necessary to combat pollution and prevent potential health issues. Hisense central air conditioners are also equipped with NANOETM (nano-water ion) technology, which targets odors at their source. Through the use of OH radicals, it breaks down odor molecules, eliminating smells rather than merely masking them. Furthermore, this technology offers additional benefits like PM2.5 filtration and antibacterial properties. This combination of features ensures that users enjoy clean, fresh air along with a comfortably cool environment during the summer months. When it comes to energy efficiency and sustainability, Hisense central air-conditioning units excel. While some may perceive the upfront costs as high compared to traditional air conditioners, the long-term savings cannot be overlooked. For instance, with larger homes requiring multiple air conditioners to cool individual rooms, the cumulative energy usage often matches or exceeds that of a single central air-conditioning system. Additionally, the lifespan of standard air conditioners typically ranges between 8 to 10 years, whereas central air conditioners can last up to 15 to 20 years. When considering the expenses associated with replacing multiple conventional units, the economic advantages of Hisense central air conditioners become apparent. Hisense’s central air-conditioning systems provide numerous benefits that are reshaping the air-conditioning market. They deliver not only cooling but also fresh, healthy air to the entire household. In such an environment, summer heat becomes manageable, offering relief and comfort.

Digital Timer Switch Socket

Instruction Manual

1. Features

Clock display, 10 sets of adjustable timed power control, randomized power control, manual switch and optional DST setup.

2. First time charging

This timer contains a rechargeable battery. It is normal that the new/old model runs out of battery if it wasn`t being charged for a long period of time. In this case, the screen will not turn on.

To charge : simply plug the timer to a power outlet. The charging time should take at least 15 minutes.

If the screen doesn`t light up or displays garbled characters, simply reboot the system by pressing the [RESET" button.

3. Set clock


Hold [CLOCK" button and [WEEK" button to adjust week.

Hold [CLOCK" button and [HOUR" button to adjust hour.

Hold [CLOCK" button and [MINUTE" button to adjust minute.

Hold [CLOCK" button and [TIMER" button to select 12 hour/24 hour display.

Hold [CLOCK" button and [ON/AUTO/OFF" button to enable/disable DST (daylight-saving-time).

4. Set timer

Press [TIMER" button, select and set timer. Setting rotation : 1on, 1off, 2on, 2off, ...... , 10on, 10off.

Press [HOUR" button to set hour for timer.

Press [MIN" button to set minute for timer.

Press [WEEK" button to set weekday for timer. Multiple weekdays can be selected. ex: if selected [MO", the timer will only apply on every Monday; if selected [ MO, WE, FR", the timer will apply on every Monday, Wednesday and Friday.


Press [RES/RCL" button to cancel the selected on or off timer. The screen will show "-- -- : -- --" , the timer is canceled.

Press [RES/RCL" button again to reactivate the timer.


When timers are set, press [CLOCK" to quit timer setting and return to clock.

5. Random function


Press [RANDOM" button to activate random function, press again to cancel function.

System only runs random function when [AUTO" is on.

Random function will automatically start the timer from 2 to 32 minutes after the setting.

ex : if timer 1on was set to 19:30 with the random function on, the timer will activate randomly between 19:33 to 20:03.

if timer 1off was set to 23:00 with the random function on, the timer will activate randomly between 23:02 to 23:32.

To avoid overlapping, make sure to leave a minimum of 31 minutes gap between different sets of timer.

6. Manual control

Displayed features:

ON : socket turns on.

OFF : socket turns off.

AUTO : socket turns on/off automatically via timer.

Manual ON setting

Press [ON/AUTO/OFF" button to switch from [AUTO" to [ON".

This mode allows socket of the device to power up. Power indicator will light up.

Manual OFF setting

Press [ON/AUTO/OFF" button to switch from [AUTO" to [OFF".

This mode turns socket of the device off. Power indicators will turn off.

7. Electrical parameters

Operating voltage : 230VAC

Battery : NiMh 1.2V

Power consumption : < 0.9W

Response time : 1 minute

Power output : 230VAC/16A/3680W

Q&A

Q: Why won`t my timer turn on?

A: It`s out of battery, you can charge the timer by plugging onto any power outlet. Charge the device for at least 15 minutes. Then press [RESET " button to reset the device.

Q: Can I set seconds of the timer?

A: No, the smallest time unit is minute.

Q: Does my timer keeps old settings without being plugged onto a power outlet?

A: Yes, the timer has an internal battery, it allows the timer to save settings without a power outlet.

Q: Is the battery rechargeable?

A: Yes, the battery is rechargeable. We recommend to charge it for 4 hours so the battery is fully charged.

Q: Does the timer needs internet connection?

A: The timer does not need internet.

Q: Does the screen have back light function?

A: It doesn`t support back light.

Digital Timer Socket, Timing Switch Socket, Electronic Timer Socket, Timer Socket